Parameter Index

Display Name on Schematic UI Tab UI Name
AddtlTranParamsTAHB Initial Guess Advanced Transient Settings - Transient Other
ArcLevelMaxStep Solver Advanced Continuation Parameters - Arc Level Max Step
ArcMaxStep Solver Advanced Continuation Parameters - Arc Max Step
ArcMaxValue Solver Advanced Continuation Parameters - Arc Max Value
ArcMinValue Solver Advanced Continuation Parameters - Arc Min Value
AvailableRAMsize Display Only editable on schematic
ConvMode Solver Convergence Mode (In Convergence Section, Check box)
Freq[i] Freq Frequency (In Edit Section)
FundOversample Params Fundamental Oversample (In FFT section)
GMRES_Restart Solver Advanced Krylov Parameters - Krylov Restart Length
GuardThresh Solver Matrix Bandwidth (In Memory Management section)
HBAHB_Enable Initial Guess Harmonic Balance Assisted Harmonic Balance
InFile Initial Guess File (Initial Guess section)
IV_RelTol Initial Guess Advanced Transient Settings - Transient IV_RelTol
KrylovLooseIters Solver Advanced Krylov Parameters - Loose Iterations
KrylovLooseTol Solver Advanced Krylov Parameters - Loose Tolerance
KrylovMaxIters Solver Advanced Krylov Parameters - Max Iterations
KrylovPackingThresh Solver Advanced Krylov Parameters - Packing Threshold
KrylovPrec Solver Advanced Krylov Parameters - Preconditioner
KrylovSS_Tol Solver Advanced Krylov Parameters - Krylov Noise Tolerance
KrylovTightTol Solver Advanced Krylov Parameters - Tight Tolerance
KrylovUsePacking Solver Advanced Krylov Parameters - Matrix Packing (check box)
MaxIters Solver Max Iterations (In Convergence section)
MaxOrder Freq Maximum mixing order
MaxShrinkage Solver Advanced Krylov Parameters - Max Step Shrinkage
MaxStepRatio Solver Advanced Krylov Parameters - Max Step Ratio
MaxTimeStep Initial Guess Advanced Transient Settings - Transient Max Time Step
MergeSS_Freqs Small-Sig Merge small- and large-signal frequencies
OneToneTranTAHB Initial Guess Advanced Transient Settings - Use only Freq(1) for transient
Order[i] Freq Order (in Edit section)
Other Display Other
OutFile Initial Guess File (Final Solution section)
OutputTranDataTAHB Initial Guess Advanced Transient Settings - Save transient data to dataset
Oversample[i] Params Oversample (in FFT section, click more)
PackFFT Solver FFT Options (In Memory Management section)
RecalculateWaveforms Solver Use Dynamic Waveform recalculation (In Memory Management section)
Restart Initial Guess Regenerate Initial Guess for ParamSweep (check box)
SamanskiiConstant Solver Matrix Re-use (Matrix Solver section)
Start Sweep Start
StatusLevel Freq Status Level (Levels section)
SteadyStateMinTime Initial Guess Advanced Transient Settings - Min Time for detecting steady state
Step Sweep Step-size
Stop Sweep Stop
StopTime Initial Guess Advanced Transient Settings - Transient Stop Time
SweepVar Sweep Parameter to sweep
TAHB_Enable Initial Guess Transient Assisted Harmonic Balance
UseAllSS_Freqs Small-Sig Use all small-signal frequencies
UseCompactFreqMap Solver Use compact frequency map (in Memory Management section)
UseInFile InitialGuess Use Initial Guess
UseKrylov Solver Solver Type
UseOutFile Initial Guess Write Final Solution
 

Privacy Statement  | Terms of Use  | Legal | Contact Us  | © Agilent 2000-2008 