Using the HSPICE Transient Controller

The HS_Tran controller is available on the Signal Integrity-Verification component palette. When using the HS_Tran controller, other controllers such as DC or AC cannot be present in the design. Also, no DSP cosimulation is allowed such as an ADS Ptolemy cosimulation. If an additional controller is present, the simulator will terminate the simulation with an error message.

The unencrypted portion of the design can contain only linear devices, and selected voltage and current sources. The following table lists the allowed sources.

Sources allowed for encrypted HSPICE Transient Simulation
Component Description
The allowed voltage sources are:
  V_DC DC
VtStep Step
VtPulse Pulse
VtPWL Piecewise Linear
VtExp Exponential Decay
VtSine Decaying Sine Wave
VtSFFM Single Frequency FM
VtBitSeq Bit Sequence
VtImpulse Impulse
VTLFSR LFSR
The allowed current sources are:
  I_DC DC
ItStep Step
ItPulse Pulse
ItPWL Piecewise Linear
ItExp Exponential Decay
ItSine Sine
 

Privacy Statement  | Terms of Use  | Legal | Contact Us  | © Agilent 2000-2008 