LCHighpassST (Singly Terminated Highpass Filter)

Symbol

Parameters
Name Description Unit Default
Fs Stopband frequency GHz 1
Fp Passband corner frequency GHz 2
Ap Passband attenuation dB 3
As Stopband attenuation dB 20
N Order of filter None 0
ResponseType Type of filter response None Maximally Flat
Termination Open or short load termination None Short Termination
Rg Source impedance Ohm 50
MaxRealizations Maximum number of realizations during synthesis None 25

Notes
  1. A singly terminated highpass filter provides a highpass frequency response between the input (pin 1) and output (pin 2) ports. This component has a real, non-zero source termination and either an open or short at the load termination.
  2. The type of frequency response (i.e. Chebyshev, Elliptical, etc.) depends on the parameter ResponseType. The transition bands of the frequency response depend on the filter order.
  3. The filter order is either set manually or is calculated by the passband and stopband frequencies and attenuations.

Example

A chebyshev highpass filter (Chebyshev Highpass Filter) was designed for 20 dB attenuation at 1 GHz and 3 dB attenuation at 2 GHz with matched 50 ohm terminations. This resulted in a filter order of N=4.

Chebyshev Highpass Filter
 