2-Tone Nonlinear Simulations > Spectrum, Gain, TOI and 5thOI Points vs. Frequency

Description

This simulation setup is identical to the HB2Tone schematic, except that the center frequency of the two input tones is swept. It simulates the spectrum, output power, power gain, and intermodulation distortion of a device or amplifier all versus frequency. A sample power amplifier is provided. You must replace this amplifier with your own device or amplifier, and modify the biases, as needed.

Needed to Use Schematic

A device or an amplifier using nonlinear model(s)

Main Schematic Settings

Range of center frequencies of the two input tones, the frequency spacing between them, maximum order of the intermodulation terms to be computed, and the available source power (from both tones). The source and load impedances at the fundamental and harmonic frequencies can also be set.

Data Display Outputs

All versus the center frequency of the two tones:

Schematic Name

HB2ToneFswp

Data Display Name

HB2ToneFswp.dds

Note

When simulating a device, setting the source and load impedances at the fundamental and harmonic frequencies might be useful. However, when simulating an amplifier that already has source and load impedance matching networks, leaving all these impedances at 50 ohms might be suitable.

 