Lumped Multi-Element Z-Y Matching Networks > Rload, Series L, Shunt C, Series L/C for Desired Z
Description
This schematic synthesizes a network that converts a load resistance to an arbitrary impedance at a single frequency. Starting from a resistance, RL, the network generates an impedance via a series L - shunt C - series L ladder network.
| Note For certain desired impedances, one of the calculated inductor values will be negative. This negative inductor must be replaced with a capacitor. The correct capacitor value when such a replacement is necessary is calculated on the data display. |
One limitation of this network is that it cannot generate impedances such that real(Zdesired)*(1+Q**2)/RL <1 .
Main Schematic Settings
Desired impedance, load resistance, frequency of match, Q of impedance transformation network
Data Display Outputs
- L and C component values of the network
- Generated impedance versus frequency, on a Smith chart
- Reflection coefficient versus frequency (dB) looking back into the network from the output resistor, RL, when the other end of the network is terminated in the complex conjugate of the desired impedance
Schematic Name
Zdesired3M
Data Display Name
Zdesired3M.dds
Privacy
Statement
|
Terms of Use
|
Legal |
Contact Us
|