Lumped Multi-Element Z-Y Matching Networks > Rload, Shunt C, Series L, Series C, Shunt L/C to Match Shunt R-C or R-L Device

Description

Given a shunt R-C equivalent input or output circuit of a device, this schematic computes component values of a network in order to conjugately match the device to an output resistance. (The shunt R-C network can be converted to a shunt R-L network if the capacitance is set to a negative value, with formula given on the schematic.) Starting from a resistance, RL, the networks generate the complex conjugate impedance via a shunt C - series L - series C - shunt L ladder network.

Note
For certain desired admittances, one of the calculated inductor values will be negative. This negative inductor must be replaced with a capacitor. The correct capacitor value when such a replacement is necessary is calculated on the data display.

Admittances in only one region (hashed in the figure shown here) of the Smith chart can be generated with this network. Rdev must be < RL, where Rdev is the device's resistance and RL is the external load resistance.

Main Schematic Settings

Device equivalent circuit (Shunt R-C or Shunt R-L) component values, load resistance, frequency of match, Q of admittance transformation network

Data Display Outputs

Schematic Name


Ymatch2M

Data Display Name


Ymatch2M.dds

 