Lumped Multi-Element Z-Y Matching Networks > Rload, Shunt C, Series L, Shunt C Shunt R-C or R-L Device

Description

Given a shunt R-C equivalent input or output circuit of a device, this schematic computes component values of two networks to conjugately match the device to an output resistance. (The shunt R-C network can be converted to a shunt R-L network if the capacitance is set to a negative value, with formula given on the schematic.) Starting from a resistance, RL, the network generates the complex conjugate admittance via a shunt C - series L - shunt C ladder network. If Rdev/RL is > (Q**2 +1 ), where Rdev is the device's resistance and RL is the external load resistance, then this network cannot be used.

Main Schematic Settings

Device equivalent circuit (Shunt R-C or Shunt R-L) component values, load resistance, frequency of match, Q of admittance transformation network

Data Display Outputs

Schematic Name


Ymatch1M

Data Display Name


Ymatch1M.dds

 

Privacy Statement  | Terms of Use  | Legal | Contact Us  | © Agilent 2000-2008 