MTaper (Microstrip Taper Component)
Symbol 
Parameters
| Name | Description | Unit | Default |
|---|---|---|---|
| Subst | Microstrip substrate name | None | MSub1 |
| F | Design frequency | GHz | 1 |
| Z1 | Characteristic impedance at port 1 | Ohm | 50 |
| Z2 | Characteristic impedance at port 2 | Ohm | 25 |
| Lphys | Physical line length (set to zero if Lelec specified) | mil | 0 |
| Lelec | Line length in wavelengths (set to zero if Lphys specified) | None | 0.10 |
Notes
- MTaper designs a microstrip tapered line given the substrate, desired characteristic impedance, and physical or electrical length.
- Since the design uses the models inherent to ADS to compute the line width and length, there is no need for a dedicated Simulation Assistant, Optimization Assistant, or Display Assistant.
- For proper operation, either Lphys or Lelec must be zero.
- Z1 and Z2 are used to determine the widths at each end of the taper component. Refer to the discussion of the MTAPER component in the Microstrip Components documentation for a more detailed description of this component.
- A SmartComponent subnetwork is empty until the Design Assistant is used to generate the design. Refer to Design Assistant.
Privacy
Statement
|
Terms of Use
|
Legal |
Contact Us
|
© Agilent 2000-2008 ![]()