MTaper (Microstrip Taper Component)


Symbol

Parameters
Name Description Unit Default
Subst Microstrip substrate name None MSub1
F Design frequency GHz 1
Z1 Characteristic impedance at port 1 Ohm 50
Z2 Characteristic impedance at port 2 Ohm 25
Lphys Physical line length (set to zero if Lelec specified) mil 0
Lelec Line length in wavelengths (set to zero if Lphys specified) None 0.10

Notes
  1. MTaper designs a microstrip tapered line given the substrate, desired characteristic impedance, and physical or electrical length.
  2. Since the design uses the models inherent to ADS to compute the line width and length, there is no need for a dedicated Simulation Assistant, Optimization Assistant, or Display Assistant.
  3. For proper operation, either Lphys or Lelec must be zero.
  4. Z1 and Z2 are used to determine the widths at each end of the taper component. Refer to the discussion of the MTAPER component in the Microstrip Components documentation for a more detailed description of this component.
  5. A SmartComponent subnetwork is empty until the Design Assistant is used to generate the design. Refer to Design Assistant.
 

Privacy Statement  | Terms of Use  | Legal | Contact Us  | © Agilent 2000-2008 

Contents
Additional Resources