BIPHASE_RX_REFERENCE_PULSER

This component outputs the same waveform as BIPHASE_TX_PULSE_GENERATOR when the data input is all 1s. The waveform output from this test block represents a bi-phase modulated UWB waveform. The input data bits are spread using a spreading code. The pulse shape output is determined by selecting PULSE_SHAPE_GENERATOR sub-components; for details, refer to PULSE SHAPE GENERATOR.

Subnetwork

Parameters
Name Description Default Unit Type Range
ChipsPerBit Number of pulses transmitted for each bit 1   Integer >1
ChipInterval Time between pulses 1 nsec Time Real >0
PulseWidth Width of output pulse 250 psec Time Real >0
PulseEnergy_joule Total energy of the output pulse in Joules. 1e-12   Real >0
DoubletSeparation Time between the positive and negative peaks of the waveform 350 psec Time Real >0
TStep Time step of the simulation 10 psec Time Real >0
Inputs
Pin Name Description Signal Type
1 Spreading Code Input Coding sequence used to spread data being transmitted input as binary bits. Integer
Outputs
Pin Name Description Signal Type
2 Pulse Output Outputs pulse with shape determined by which pulse generator subcomponent is selected. Float
 