PULSE_SHAPE_GENERATOR

To select a pulse shape, push into the PULSE_SHAPE_GENERATOR component; enable the component for the desired pulse shape; disable the unused components.

In simulations, TStep is approximately PulseWidth/10. One pulse waveform is output each time the input signal amplitude equals 1. The total waveform width is 3.603×PulseWidth. When pulses overlap, the first pulse is truncated.

Subnetwork

Pin Name Description Signal Type
1 Trigger Input An input impulse with magnitude 1 triggers PULSE_SHAPE_GENERATOR to output pulse Float
Pin Name Description Signal Type
2 Pulse Output Outputs pulse with shape determined by pulse generator subcomponent Float

The GAUSSIAN_DOUBLET_UWB_Transmitter
generates a pair of Gaussian monopulse waveforms of opposite polarity.

Name Description Default Unit Type Range
PulseWidth Width of output pulse at 1/2 maximum amplitude of each of Gaussian monopulses that make up the doublet 250 psec Time Real >0
DoubletSeparation Time between the positive and negative peaks of the waveform 250 psec Time Real >0
PulseEnergy_joule Total energy of the output pulse in Joules. This value will not be calibrated when the individual pulses of the doublet overlap 1e-12   Real >0
TStep Time step of the simulation 10 psec Time Real >0
Pin Name Description Signal Type
1 Trigger Input An input impulse with magnitude 1 triggers the output of a Gaussian doublet pulse Float
Pin Name Description Signal Type
2 Pulse Output Outputs Gaussian doublet pulse waveform Float

The GAUSSIAN_FIRST_DERIVATIVE_UWB_Transmitter
outputs a pulse with the shape of the first derivative of a Gaussian monopulse when a 1 is input.

Name Description Default Unit Type Range
PulseWidth Width of output pulse at 1/2 maximum amplitude of Gaussian monopulse of which the output waveform is a first derivative 250 psec Time Real >0
PulseEnergy_joule Total energy of the output pulse in Joules 1e-12   Real >0
TStep Time step of the simulation 10 psec Time Real >0
Pin Name Description Signal Type
1 Trigger Input An input impulse with magnitude 1 triggers the output of a Gaussian first derivative pulse Float
Pin Name Description Signal Type
2 Pulse Output Outputs Gaussian first derivative waveform Float

The GAUSSIAN_MONOPULSE_UWB_Transmitter
outputs a Gaussian-shaped monopulse when a 1 is input.

Name Description Default Unit Type Range
PulseWidth Width of output pulse at 1/2 maximum amplitude 250 psec Time Real >0
PulseEnergy_joule Total energy of the output pulse in Joules 1e-12   Real >0
TStep Time step of the simulation 10 psec Time Real >0
Pin Name Description Signal Type
1 Trigger Input An input impulse with magnitude 1 triggers the output of a Gaussian monopulse Float
Pin Name Description Signal Type
2 Pulse Output Outputs pulse with single Gaussian shaped pulse Float

The GAUSSIAN_SECOND_DERIVATIVE_UWB_Transmitter
outputs a pulse with the shape of the second derivative of a Gaussian monopulse when a 1 is input.

Name Description Default Unit Type Range
PulseWidth Width of output pulse at 1/2 maximum amplitude of Gaussian monopulse of which the output waveform is a second derivative 250 psec Time Real >0
PulseEnergy_joule Total energy of the output pulse in Joules 1e-12   Real >0
TStep Time step of the simulation 10 psec Time Real >0
Pin Name Description Signal Type
1 Trigger Input An input impulse with magnitude 1 triggers the output of a Gaussian second derivative pulse Float
Pin Name Description Signal Type
2 Pulse Output Outputs Gaussian second derivative waveform Float
 