UWB_RX_Correlator_with_Integrator_Reset_UWB_Receiver


This correlator multiplies the receive signal with a reference signal and integrates the results over a period of time. The integrator in the correlator integrates the multiplier output signal between >1 values at the Reference Pulse Input pin 2; it resets the integrator value to 0 and restarts the integration when a pulse is received on this pin.

Pin Name Description Signal Type
1 Antenna Input UWB receiver input waveform Float
2 Reference Pulse Input Reference pulse waveform for correlator Float
4 Integrator Reset Input   Integer
Pin Name Description Signal Type
3 Output Output from correlator integrator Float
 