vfc_tran()

Returns the transient frequency-selective voltage

Syntax
y = vfc_tran(vPlus, vMinus, fundFreq, harmNum)

Arguments
Name Description Range Type Required
vPlus voltage at the positive terminal (-∞, ∞) real, complex yes
vMinus voltage at the negative terminal (-∞, ∞) real, complex yes
fundFreq fundamental frequency [0, ∞) real yes
harmNum harmonic number of the fundamental frequency [0, ∞) integer yes

Examples

a = vfc_tran(vOut, 0, 1GHz, 1)

Defined in

$HPEESOF_DIR/expressions/ael/circuit_fun.ael

See Also

ifc_tran(), pfc_tran()

Notes/Equations

This measurement gives the RMS voltage across any two nodes at a particular frequency of interest. The fundamental frequency determines the portion of the time-domain waveform to be converted to frequency domain. This is typically one full period corresponding to the lowest frequency in the waveform. The harmonic number is the fundamental frequency at which the voltage is requested (positive integer value only).

 

Privacy Statement  | Terms of Use  | Legal | Contact Us  | © Agilent 2000-2008 