Lumped

AIRIND1 (Air Core Inductor)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for AIRIND1 in ADS.

GENESYS Symbol ADS Component
INDUCTOR AIRIND1
All other symbols AIRIND1 using the Intermediate Subcircuit named genesyslib_AIRIND1_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
N N  
D D  
L L  
WD WD  
RHO Rho  
  Temp Set to the ADS default value (blank)
  All other ADS parameters are set to their default values.  

CAP (Ideal Capacitor)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for C in ADS.

GENESYS Symbol ADS Component
CAPACITOR C
All other symbols C using the Intermediate Subcircuit named genesyslib_CAP_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
C C  
  All other ADS parameters are set to their default values.  

CAPQ (Capacitor with Q)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for CAPQ in ADS.

GENESYS Symbol ADS Component
CAPACITOR CAPQ
All other symbols CAPQ using the Intermediate Subcircuit named genesyslib_CAPQ_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
C C  
QC Q  
F F  
MODE Mode  
RDC RDC = 0 See note 1.
  Temp Set to the default value (blank).
  All other ADS parameters are set to their default values.

Notes

  1. The GENESYS parameter RDC has an effect only at DC. The ADS parameter Rdc has an effect at all frequencies.

CIR3 (Ideal 3-port Circulator)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for Circulator in ADS.

GENESYS Symbol ADS Component
CIR3 Circulator
All other symbols Circulator using the Intermediate Subcircuit named genesyslib_CIR3_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
Z Z1 = Z  
  Z2 = Z  
  Z3 = Z  
  All other ADS parameters are set to their default values.

DIPOLE (Dipole Antenna)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS ANTENNA documentation or refer to the documentation for AntLoad in ADS.

GENESYS Symbol ADS Component
ANTENNA AntLoad
All other symbols AntLoad using the Intermediate Subcircuit named genesyslib_DIPOLE_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
LEN Length  
LD RatioLR = 2*LD
  AntType = DIPOLE  
  All other ADS parameters are set to their default values.

GAIN (Ideal Gain Block)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model.

GENESYS Symbol ADS Component
BLOCK GAIN
All other symbols GAIN using the Intermediate Subcircuit named genesyslib_GAIN_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
A A  
S S = S*3.32193 Converts from db/octave to db/decade
F F  
  All other ADS parameters are set to their default values.  

IND (Ideal Inductor)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for L in ADS.

GENESYS Symbol ADS Component
INDUCTOR L
All other symbols L using the Intermediate Subcircuit named genesyslib_IND_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
L L  
  All other ADS parameters are set to their default values.  

INDQ (Inductor with Q)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for INDQ in ADS.

GENESYS Symbol ADS Component
INDUCTOR INDQ
All other symbols INDQ using the Intermediate Subcircuit named genesyslib_INDQ_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
L L  
QL Q See note 1.
F F  
MODE Mode See note 1.
RDC Rdc = 0 See note 2.
  Temp Set to the default value (blank).
  All other ADS parameters are set to their default values.

Notes

  1. For low Q (10 or less) and Mode not set to 1 (Proportional to frequency), the ADS and GENESYS simulation results start to differ for frequencies below F.
  2. The GENESYS parameter RDC has an effect only at DC. The ADS parameter Rdc has an effect at all frequencies.

ISOLATOR (Ideal Isolator)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for IsolatorSML in ADS.

GENESYS Symbol ADS Component
BLOCK IsolatorSML
All other symbols IsolatorSML using the Intermediate Subcircuit named genesyslib_ISOLATOR_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
Z Z1 = Z  
  Z2 = Z  
  All other ADS parameters are set to their default values.  

MONOPOLE (Monopole Antenna)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for AntLoad in ADS.

GENESYS Symbol ADS Component
ANTENNA AntLoad
All other symbols AntLoad using the Intermediate Subcircuit named genesyslib_MONOPOLE_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
LEN Length  
LD RatioLR  
  AntType = DIPOLE  
  All other ADS parameters are set to their default values.  

MUCQ<n> (<n> Mutually Coupled Coils)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MUC2 thru MUC10 in ADS.

GENESYS Symbol ADS Component
  MUC2 thru MUC10
All other symbols MUC<n> using the Intermediate Subcircuit named genesyslib_MUCQ<n>_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
Ln Ln  
Kij Kij  
Qn   Not supported by the ADS component.
RDn Rn = 0 See note 1.
F   Not supported by the ADS component.
MODE   Not supported by the ADS component.
  Temp Set to the default value (blank).
  All other ADS parameters are set to their default values.  

Notes

  1. The GENESYS parameters RDCn have an effect only at DC. The ADS parameters Rn have an effect at all frequencies.

MUI (Two Mutually Coupled Inductors)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MUC2 in ADS.

GENESYS Symbol ADS Component
MUTUAL MUC2
All other symbols MUC2 using the Intermediate Subcircuit named genesyslib_MUI_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
L1 L1  
L2 L2  
K K12  
  R1 = 0  
  R2 = 0  
  All other ADS parameters are set to their default values.

OPA (Operational Amplifier)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for OpAmpIdeal in ADS.

GENESYS Symbol ADS Component
  OpAmpIdeal
All other symbols OpAmpIdeal using the Intermediate Subcircuit named genesyslib_OPA_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
RI Rdiff  
RO Rout  
G Gain  
F BW  
  All other ADS parameters are set to their default values.

PFC (Parallel LC Resonator)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for PLCQ in ADS.

GENESYS Symbol ADS Component
PFC PLCQ
All other symbols PLCQ using the Intermediate Subcircuit named genesyslib_PFC_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
F  
C C  
QL Ql  
QC Qc  
  Fl = 1 MHz  
  ModL = Constant  
  Fc = 1 MHz  
  ModC = Constant  
  All other ADS parameters are set to their default values.  

PFL (Parallel LC Resonator)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for PLCQ in ADS.

GENESYS Symbol ADS Component
PFC PLCQ
All other symbols PLCQ using the Intermediate Subcircuit named genesyslib_PFL_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
F  
L L  
QL Ql  
QC Qc  
  Fl = 1 MHz  
  ModL = Constant  
  Fc = 1 MHz  
  ModC = Constant  
  All other ADS parameters are set to their default values.  

PLC (Parallel LC Network)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for PLCQ in ADS.

GENESYS Symbol ADS Component
PFC PLCQ
All other symbols PLCQ using the Intermediate Subcircuit named genesyslib_PLC_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
L L  
C C  
QL Ql  
QC Qc  
  Fl = 1 MHz  
  ModL = Constant  
  Fc = 1 MHz  
  ModC = Constant  
  All other ADS parameters are set to their default values.

PRC (Parallel RC Network)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for PRC in ADS.

GENESYS Symbol ADS Component
PRC PRC
All other symbols PRC using the Intermediate Subcircuit named genesyslib_PRC_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
R R  
C C  
Qc   Not supported by the ADS component.
  Temp Set to the default value (blank).
  All other ADS parameters are set to their default values.  

PRL (Parallel RL Network)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for PRL in ADS.

GENESYS Symbol ADS Component
PRL PRL
All other symbols PRL using the Intermediate Subcircuit named genesyslib_PRL_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
R R  
L L  
QL   Not supported by the ADS component.
  Temp Set to the default value (blank).
  All other ADS parameters are set to their default values.

PRX (Parallel RLC Network)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for PRLC in ADS.

GENESYS Symbol ADS Component
PRX PRLC
All other symbols PRLC using the Intermediate Subcircuit named genesyslib_PRX_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
R R  
L L  
C C  
QL   Not supported by the ADS component.
QC   Not supported by the ADS component.
  Temp Set to the default value (blank).
  All other ADS parameters are set to their default values.  

RES (Ideal Resistor)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for R in ADS.

GENESYS Symbol ADS Component
RESISTOR R
All other symbols R using the Intermediate Subcircuit named genesyslib_RES_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
R R  
  All other ADS parameters are set to their default values.  

SFC (Series LC Resonator)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for SLCQ in ADS.

GENESYS Symbol ADS Component
SFC SLCQ
All other symbols SLCQ using the Intermediate Subcircuit named genesyslib_SFC_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
F  
C C  
QL Ql  
QC Qc  
  Fl = 1 MHz  
  ModL = Constant  
  Fc = 1 MHz  
  ModC = Constant  
  All other ADS parameters are set to their default values.  

SFL (Series LC Resonator)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for SLCQ in ADS.

GENESYS Symbol ADS Component
SFC SLCQ
All other symbols SLCQ using the Intermediate Subcircuit named genesyslib_SFL_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
F  
L L  
QL Ql  
QC Qc  
  Fl = 1 MHz  
  ModL = Constant  
  Fc = 1 MHz  
  ModC = Constant  
  All other ADS parameters are set to their default values.  

SLC (Series LC Network)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for SLCQ in ADS.

GENESYS Symbol ADS Component
SFC SLCQ
All other symbols SLCQ using the Intermediate Subcircuit named genesyslib_SLC_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
L L  
C C  
QL Ql  
QC Qc  
  Fl = 1 MHz  
  ModL = Constant  
  Fc = 1 MHz  
  ModC = Constant  
  All other ADS parameters are set to their default values.  

SRC (Series RC Network)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for SRC in ADS.

GENESYS Symbol ADS Component
See note 1 SRC
All other symbols SRC using the Intermediate Subcircuit named genesyslib_SRC_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
R R  
C C  
Qc   Not supported by the ADS component.
  Temp Set to the default value (blank).
  All other ADS parameters are set to their default values.  

Notes

  1. The symbol for the ADS SRC component is 7/8 inch long rather than the usual 1 inch. This means that an intermediate subcircuit (called genesyslib_SRC_SRC) is used to map the 1 inch GENESYS symbol to the 7/8 inch ADS symbol.

SRL (Series RL Network)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for SRL in ADS.

GENESYS Symbol ADS Component
SRL SRL
All other symbols SRL using the Intermediate Subcircuit named genesyslib_SRL_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
R R
L L  
Ql   Not supported by the ADS component.
  Temp Set to the default value (blank).
  All other ADS parameters are set to their default values.  

SRX (Series RLC Network)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for SRLC in ADS.

GENESYS Symbol ADS Component
SRX SRLC
All other symbols SRLC using the Intermediate Subcircuit named genesyslib_SRX_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
R R  
L L  
C C  
QL   Not supported by the ADS component.
QC   Not supported by the ADS component.
  Temp Set to the default value (blank).  
  All other ADS parameters are set to their default values.

TFC (Thin Film Capacitor)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for TFC in ADS.

GENESYS Symbol ADS Component
CAPACITOR TFC
All other symbols TFC using the Intermediate Subcircuit named genesyslib_TFC_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
W W  
L L  
T T  
Er Er  
Rho Rho = Rho/1.42 GENESYS is relative to copper. ADS is relative to gold.
TanD TanD  
  All other ADS parameters are set to their default values.

TORIND (Toroidal Core Inductor)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for CIND2 in ADS.

GENESYS Symbol ADS Component
INDUCTOR CIND2
All other symbols CIND2 using the Intermediate Subcircuit named genesyslib_TORIND_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
N N  
AL AL  
Rs R  
Qc Q  
Fq Freq  
  All other ADS parameters are set to their default values.

TRF (Transformer)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for TF in ADS.

GENESYS Symbol ADS Component
TRANSFORMER TF
All other symbols TF using the Intermediate Subcircuit named genesyslib_TRF_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
P T= P/S  
S    
OPTION   OPTION must be 0 (indicating turns rather then impedance ratio).
  All other ADS parameters are set to their default values.  

TWO (2-port data file)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for S2P in ADS, or intermediate subcircuits.

GENESYS Symbol ADS Component
see note 1 S2P
All other symbols S2P using the Intermediate Subcircuit named genesyslib_TWO_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
FILENAME File If the filename uses a relative path, you will need to edit the path so that ADS can find the file.
  Type = Touchstone  
  All other ADS parameters are set to their default values.  

Notes

  1. The symbol for the ADS S2P component is a simple rectangle. The GENESYS TWO model is typically used with a variety of symbols, (amplifiers, BJTs, FETS, etc.) an intermediate sub-circuit is almost always used so that the GENESYS symbol appears in ADS.

XTL (Crystal)

Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for XTAL1 in ADS.

GENESYS Symbol ADS Component
CRYSTAL XTAL1
All other symbols XTAL1 using the Intermediate Subcircuit named genesyslib_XTL_<SYMBOL>

Parameter Mapping

GENESYS ADS Comments
R R  
L L  
Cm C  
Co Cp  
  OT = 1  
  Temp Set to the default value (blank).
  All other ADS parameters are set to their default values.

 

Privacy Statement  | Terms of Use  | Legal | Contact Us  | © Agilent 2000-2008 

Contents
Additional Resources