Microstrip
MBN (Microstrip Bend)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MBEND2 in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| MBN | MBEND2 |
| All other symbols | MBEND2 using the Intermediate Subcircuit named genesyslib_MBN_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W | W | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
MCN<n> (Multiple Coupled Microstrip Lines)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for PCLIN2, PCLIN3,...,PCLIN10 in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| <n>-Lines | PCLIN<n> |
| All other symbols | PCLIN<n> using the Intermediate Subcircuit named genesyslib_MCN<n>_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W | W |
|
| S |
See note 1. | |
| L | L | |
| SUBST | Subst | |
| S |
See note 1. | |
| Layer |
See note 1. | |
| All other ADS parameters are set to their default values. | ||
Notes
- For ADS model PCLIN, S<n> refers to a coordinate of gaps across microstrip lines from an origin (wall), whereas for MCN, S<n> refers to a gap width. The translation between the parameters follows:
- (a) PCLIN.S1 = W
- (b) PCLIN.S<i> = W + (i * W) + Sum(MCN.S<j>, j=1...(n-1)) for i=2...n.
- All microstrip lines lay on the same layer.
MCN4A (Asymmetric Coupled Microstrip Lines)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MACLIN in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| TRL_COUPLED | MACLIN |
| All other symbols | MACLIN using the Intermediate Subcircuit named genesyslib_MCN4A_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W1 | W1 | |
| W2 | W2 | |
| S1 | S | |
| L | L | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
MCP (Two Coupled Microstrip Lines)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MCLIN in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| TRL_COUPLED | MCLIN |
| All other symbols | MCLIN using the Intermediate Subcircuit named genesyslib_MCP_<SYMBOL> |
Parameter Mapping
| GENESYS Parameter | ADS Parameter | Comments |
|---|---|---|
| W | W | |
| S | S | |
| L | L | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
MCR (Microstrip Cross)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MCROS in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| MCR | MCROS |
| All other symbols | MCROS using the Intermediate Subcircuit named genesyslib_MCR_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W1 | WT | |
| W2 | WC | |
| W3 | WT | |
| W4 | WC | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
MCURVE (Microstrip Curved Bend)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MCURVE in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| MCURVE | MCURVE |
| All other symbols | MCURVE using the Intermediate Subcircuit named genesyslib_MCURVE_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W | W | |
| ANG | Angle | |
| RAD | Radius | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
MEN (Microstrip Open End)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MLEF in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| MEN | MLEF |
| All other symbols | MLEF using the Intermediate Subcircuit named genesyslib_MEN_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W | W | |
| L | 0 mil | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
MGA (Microstrip Gap)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MGAP in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| MGA | MGAP |
| All other symbols | MGAP using the Intermediate Subcircuit named genesyslib_MGA_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W | W | |
| G | S | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
MLI (Microstrip Line)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MLIN in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| MLI | MLIN |
| All other symbols | MLIN using the Intermediate Subcircuit named genesyslib_MLI_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W | W | |
| L | L | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
MRS (Microstrip Radial Stub)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MRSTUB in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| RADIAL_STUB2 | MRSTUB |
| All other symbols | MRSTUB using the Intermediate Subcircuit named genesyslib_MRS_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| R | ||
| Phi | Angle | |
| W | Wi | |
| H | See note 1. | |
| SUBST | Subst | |
| L = R - (0.5W/sin(PhiPI/360)) | ||
| All other ADS parameters are set to their default values. | ||
Notes
- Parameter value is taken from the substrate.
MST (Microstrip Step)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MSTEP in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| TRL_STEP | MSTEP |
| All other symbols | MSTEP using the Intermediate Subcircuit named genesyslib_MST_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| NAR | W1 | |
| W | W2 | |
| OPTION | See note 1. | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
Notes
- Only the symmetrical step is supported, i.e. OPTION = 0.
MTAPER (Microstrip Linearly Tapered Line)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MTAPER in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| TAPER | MTAPER |
| All other symbols | MTAPER using the Intermediate Subcircuit named genesyslib_MTAPER_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W1 | W1 | |
| W2 | W2 | |
| LEN | L | |
| SUBST | Subst | |
| All other ADS parameters are set to their default values. | ||
MTE (Microstrip Symmetrical or Asymmetrical Tee Junction)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for MTEE in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| TRL_TEE3 | MTEE |
| All other symbols | MTEE using the Intermediate Subcircuit named genesyslib_MTE_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| W1 | W1 | |
| W2 | W2 | |
| W3 | W3 | |
| SUBST | Subst | |
| OPTION | ||
| All other ADS parameters are set to their default values. | ||
MVH (Microstrip Via Hole)
Documentation in this chapter is for translation information/notes only. For more information, please see the GENESYS documentation for this model or refer to the documentation for VIA in ADS.
| GENESYS Symbol | ADS Component |
|---|---|
| See note 1 | VIA |
| All other symbols | VIA using the Intermediate Subcircuit named genesyslib_MVH_<SYMBOL> |
Parameter Mapping
| GENESYS | ADS | Comments |
|---|---|---|
| R | D1 = 2R D2 = 2R | |
| H | H = H | If H is not specified, the value is taken from the substrate specified by SUBST. |
| T | T = T | If T is not specified, the value is taken from the substrate specified by SUBST. |
| SUBST | Subst | See the comments for H and T. |
| All other ADS parameters are set to their default values. | ||
Notes
- An intermediate subcircuit is always used regardless of the symbol used in GENESYS.