Substrate Translation
The following section details translation information for substrate translation.
Mapping ADS Substrates
The following table details the transmission line technologies currently supported by the ADS link.
| Transmission Line Technologies |
Supported by the ADS Link |
| Ideal |
yes |
| Microstrip (Standard) |
yes |
| Stripline (Standard) |
yes |
| Stripline (Offset) |
yes |
| Coax |
no |
| Square Coax (Square Conductor) |
no |
| Square Coax (Round Conductor) |
no |
| Coplanar |
no |
| Coplanar with Ground |
no |
| Microstrip (Inverted) |
no |
| Microstrip (Suspended) |
no |
| Slabline (Round Rod) |
no |
MSUB (Microstrip Substrate)Substrate Mapping
| ADS |
GENESYS |
Comments |
| H |
Height |
|
| Er |
Er |
|
| Mur |
|
Not mapped. GENESYS assumes Mur = 1 |
| Cond |
Rho = 1/(Cond*1.724e-8) |
|
| Hu |
|
Not specified on GENESYS substrate |
| T |
Thick |
|
| TanD |
Tand |
|
| Rough |
Sr |
|
SSUB (Stripline Substrate)Substrate Mapping
| ADS |
GENESYS |
Comments |
| Er |
Er |
|
| Mur |
|
Not mapped. GENESYS assumes Mur = 1 |
| B |
Height |
|
| T |
Thick |
|
| Cond |
Rho = 1/(Cond*1.724e-8) |
|
| TanD |
Tand |
|
| |
Sr = 0 |
|
SSSUB (Suspended Substrate) Substrate Mapping
| ADS |
GENESYS |
Comments |
| H |
Height |
|
| Er |
Er |
|
| Mur |
|
Not mapped. GENESYS assumes Mur = 1 |
| Cond |
Rho = 1/(Cond*1.724e-8) |
|
| Hu |
|
Not a substrate parameter. |
| H1 |
|
Not a substrate parameter. |
| T |
Thick |
|
| TanD |
Tand |
|
CPWSUB (Coplanar Waveguide Substrate) Substrate Mapping
| ADS |
GENESYS |
Comments |
| H |
Height |
|
| Er |
Er |
|
| Mur |
|
Not mapped. GENESYS assumes Mur = 1 |
| Cond |
Rho = 1/(Cond*1.724e-8) |
|
| T |
Thick |
|
| TanD |
Tand |
|
| Rough |
Sr |
|
PCSUB1 (PCB Substrate) Substrate Mapping
| ADS |
GENESYS |
Comments |
| H[1] |
Height |
|
| Er |
Er |
|
| Cond |
Rho = 1/(Cond*1.724e-8) |
|
| Hu |
|
Not a substrate parameter. |
| H1 |
|
Not a substrate parameter. |
| T |
Thick |
|
| W |
|
Not a substrate parameter. |
| Sigma |
|
Not a substrate parameter. |
| TanD |
Tand |
|
MLSUBSTRATE2 (Multilayer Substrate, 2 Layers) Substrate Mapping
| ADS |
GENESYS |
Comments |
| Er |
Er |
|
| H |
Height |
|
| TanD |
Tand |
|
| T[1] |
Thick |
|
| Cond[1] |
Rho = 1/(Cond*1.724e-8) |
|
| T[2] |
|
Not a substrate parameter. |
| Cond[2] |
|
Not a substrate parameter. |
Non-Mapped Substrates
The following table lists ADS substrates with no GENESYS counterpart.
| ADS Substrate Name |
Description |
| FSUB |
Finline substrate |
| MLSUBSTRATE3 |
Multi-layer substrate, 3 layers |
| MLSUBSTRATE4 |
Multi-layer substrate, 4 layers |
| MLSUBSTRATE5 |
Multi-layer substrate, 5 layers |
| MLSUBSTRATE6 |
Multi-layer substrate, 6 layers |
| MLSUBSTRATE7 |
Multi-layer substrate, 7 layers |
| MLSUBSTRATE8 |
Multi-layer substrate, 8 layers |
| MLSUBSTRATE9 |
Multi-layer substrate, 9 layers |
| MLSUBSTRATE10 |
Multi-layer substrate, 10 layers |
| MLSUBSTRATE12 |
Multi-layer substrate, 12 layers |
| MLSUBSTRATE14 |
Multi-layer substrate, 14 layers |
| MLSUBSTRATE16 |
Multi-layer substrate, 16 layers |
| MLSUBSTRATE32 |
Multi-layer substrate, 32 layers |
| MLSUBSTRATE40 |
Multi-layer substrate, 40 layers |
| MSUBST3 |
Microstrip 3-layer substrate |
| PCSUB2 |
2-layer printed circuit substrate |
| PCSUB3 |
3-layer printed circuit substrate |
| PCSUB4 |
4-layer printed circuit substrate |
| PCSUB5 |
5-layer printed circuit substrate |
| PCSUB6 |
6-layer printed circuit substrate |
| PCSUB7 |
7-layer printed circuit substrate |
| SSSUBO |
Offset stripline substrate |
Mapping GENESYS Substrates
When a GENESYS schematic is exported to ADS, a substrate is inserted onto the ADS schematic if any component needs it. The ADS substrates supported during schematic export are:
- CPWSUB - Coplanar waveguide
- MSUB - Microstrip
- MLSUBTRATE2 - Multi-layer substrate
- SSUB - Stripline
The substrate parameters are mapped as follows:
GENESYS substrate mapped to MSUB (Microstrip substrate) Substrate Mapping
| GENESYS substrate parameter |
ADS MSUB parameter |
Comments |
| Er |
Er |
|
| Tand |
TanD |
|
| Rho |
Cond = 1/(Rho*1.724e-8) |
Rho is resistivity relative to annealed copper. Cond is conductivity in Siemens/m |
| Thick |
T |
|
| Sr |
Rough |
|
| Height |
H |
|
| LibName |
|
Not mapped. |
|
All other ADS parameters are set to their default values. |
GENESYS substrate mapped to SSUB (Stripline substrate) Substrate Mapping
| GENESYS substrate parameter |
ADS MSUB parameter |
Comments |
| Er |
Er |
|
| Tand |
TanD |
|
| Rho |
Cond = 1/(Rho*1.724e-8) |
Rho is resistivity relative to annealed copper. Cond is conductivity in Siemens/m |
| Thick |
T |
|
| Sr |
|
Not mapped. |
| Height |
B |
|
| LibName |
|
Not mapped. |
|
All other ADS parameters are set to their default values. |
GENESYS substrate mapped to CPWSUB (Coplanar waveguide substrate) Substrate Mapping
| GENESYS substrate parameter |
ADS MSUB parameter |
Comments |
| Er |
Er |
|
| Tand |
TanD |
|
| Rho |
Cond = 1/(Rho*1.724e-8) |
Rho is resistivity relative to annealed copper. Cond is conductivity in Siemens/m |
| Thick |
T |
|
| Sr |
Rough |
|
| Height |
H |
|
| LibName |
|
Not mapped. |
|
All other ADS parameters are set to their default values. |
GENESYS substrate mapped to MLSUBSTRATE2 (Multi-layer substrate) Substrate Mapping
| GENESYS substrate parameter |
ADS MSUB parameter |
Comments |
| Er |
Er |
|
| Tand |
TanD |
|
| Rho |
Cond[1] = 1/(Rho*1.724e-8) Cond[2] = 1/(Rho*1.724e-8) |
Rho is resistivity relative to annealed copper. Cond is conductivity in Siemens/m |
| Thick |
T[1] T[2] |
|
| Sr |
|
Not mapped. |
| Height |
H |
|
| LibName |
|
Not mapped. |
|
All other ADS parameters are set to their default values. |
Privacy
Statement
|
Terms of Use
|
Legal |
Contact Us
|
© Agilent 2000-2008 