QuarterWaveMatch (Quarter Wave Match)

Symbol

Summary

A quarter wave transformer network provides a broadband bandpass frequency response between the input (pin 1) and output (pin 2) ports. The source or load terminations must be unequal resistances. The matching network consists of multiple quarter wavelength transmission line elements with carefully computed characteristic impedances to provide the specified frequency response.

Parameters
Name Description Unit Default
Fp1 Frequency at lower passband edge GHz 1
Fp2 Frequency at upper passband edge GHz 2
Rg Input impedance Ohms 50
RL Load impedance Ohms 100
ResponseType Type of frequency response None Uniform
N Number of Quarter-Wave Sections (set N=0 to compute N) None 0
Rmax Maximum voltage reflection coefficient dB 20

Palette

Impedance Matching

Available Automated-Assistants

Matching Assistant, Simulation Assistant, Yield Assistant, Display Assistant, Transformation Assistant

Matching Assistant Usage

For general information, refer to Matching Assistant.

Simulation Assistant Usage

For general information, refer to Simulation Assistant.

Yield Assistant Usage

For general information, refer to Yield Assistant.

Display Assistant Usage

For general information, refer to Display Assistant.

Example

A quarter wave transformer was designed to match a 100 Ohm load impedance to a 50 ohm source impedance from 1GHz to 2 GHz. The maximum reflection coefficient was -20 dB, with a uniform distribution of the section reflection coefficients. The design resulted in N=3 sections.

Quarter Wave Transformer
 

Privacy Statement  | Terms of Use  | Legal | Contact Us  | © Agilent 2000-2008 