A tapered line transformer network provides a broadband highpass frequency response between the input (pin 1) and output (pin 2) ports. The source or load terminations must be unequal resistances. The network consists of multiple transmission line sections to approximate a tapered line.
Parameters
| Name | Description | Unit | Default |
|---|---|---|---|
| Fp | Frequency at lower passband edge (Response is Highpass) | GHz | 1 |
| Rg | Input impedance | Ohms | 50 |
| RL | Load impedance | Ohms | 100 |
| ResponseType | Type of frequency response | None | Exponential Taper |
| Rmax | Maximum voltage reflection coefficient | dB | -20 |
| N | Number of TLine Sections per wavelength | None | 0 |
Palette
Impedance Matching
Available Automated-Assistants
Matching Assistant, Simulation Assistant, Yield Assistant, Display Assistant, Transformation Assistant
Matching Assistant Usage
For general information, refer to Matching Assistant.
Simulation Assistant Usage
For general information, refer to Simulation Assistant.
Yield Assistant Usage
For general information, refer to Yield Assistant.
Display Assistant Usage
For general information, refer to Display Assistant.
Example
A tapered transformer was designed to match a 100 Ohm load impedance to a 50 ohm source impedance with a lower passband edge of 1GHz. The maximum reflection coefficient was -20 dB, with an exponential taper. The design used N=20 sections per wavelength.

Tapered Transformer
References
- Thomas R. Cuthbert, Jr., Circuit Design Using Personal Computers , John Wiley & Sons, New York, 1983.
- R. Levy, "Explicit formulas for Chebyshev impedance-matching networks," Proc. IEEE , pp. 1099-1106, June 1964.
- R. M. Cottee and W. T. Joines, "Synthesis of lumped and distributed networks for impedance matching of complex loads," IEEE Trans. Circuits Syst. , pp. 316-329, May 1979.