Parameters for RF System Budget Analysis

The recommended way to setup a budget analysis is by using the Budget controller set up dialog box. To open this dialog box, double-click the Budget controller instance from the ADS schematic design. The Budget dialog box includes three tabs, enabling you to define the following aspects of the simulation:

Setting up a Budget Analysis

The Setup tab enables you to set up the simulation for linear or nonlinear analysis specify the frequency for noise simulation, and to specify how results are output. Names used in netlists and ADS Schematics appear under Parameter Name.

RF Budget Simulation Setup Parameters
Setup Dialog Name Parameter Name Description
Simulation - Set up linear/nonlinear simulation
  Nonlinear Analysis
  Enable nonlinear analysis NonlinearAnalysis Select the checkbox to enable nonlinear analysis. Leave the checkbox unselected to enable linear analysis.
Harmonic order NonlinearHarmonicOrder Harmonic order used for P2D analysis of components that require S-parameter characterization
Max. component input power (dBm) CmpMaxPin Maximum component input power
Noise Simulation - Set up noise simulation
  Frequency span NoiseFreqSpan The frequency span used for noise simulations
Frequency step NoiseFreqStep The frequency step used for noise simulations. In the dialog box, entering a value for Frequency step automatically calculates the value for Frequency points based on the value for Frequency span.
Frequency points   Optionally, define the number of points and Frequency span to determine the Frequency step. In the dialog box, entering a value for Frequency points automatically calculates the value for Frequency step based on the value for Frequency span.
Resolution bandwidth NoiseResolutionBW Resolution bandwidth used for noise simulations
Results - Set up the format and options for displaying results after analysis
  Components in TableComponentFormat Formats output table with measurements in columns or rows
Angle unit MeasurementAngleUnit Determines the angle for output measurements in radians or degrees
Frequency unit MeasurementFrequencyUnit Determines the frequency units for output measurements in Hz, kHz, MHz, GHz, THz, or PHz
Auto format display with overwrite AutoFormatDisplay When selected, the output to the Data Display is formatted in tables and plots such that:
- Components are ordered as in the system from first to last (source to term)
- Measurements are ordered as listed in the Measurement tab
- New data overwrites the existing .dds file for the current design
Output results as comma separated values (CSV) to file OutputCSVFile Measurement data written as comma-separated values to .csv file
Run command after analysis RunCommand When Output results as comma separated values (CSV) to file is selected, enabling this parameter runs a user-defined command after analysis. The command is entered in the System Command field, and typically is used for post processing the .csv file data.
System command SystemCommand When Run command after analysis is selected, enter a command to run, such as running Excel on a PC platform. See Exporting and Post-Processing Results.

Selecting Measurements

The Measurement tab enables you to select the system cascade measurements that are evaluated per component in the schematic design. Names used in netlists and ADS Schematics appear under Parameter Name.

Note
Measurements also include a set of built-in system summary measurements, that evaluate overall system performance. These are single value system measurements and are not for each component. They are not selectable, and are always written to the CSV file and the ADS dataset.
Setup Dialog Name Parameter Name Description
Recall selected measurements from file   Populates the list of Selected Measurements from a file
Available Measurements   Select from list of available measurements to include in analysis. These are system cascade measurements for each component, or at each component input or output.
Selected Measurements Measurement[n] An ordered list determines the order in which measurements are written to the CSV file and Data Display.
To change the order:
  • Raise moves the selected measurement up
  • Lower moves the selected measurement down
  • Delete moves selected measurement(s) to the Available Measurements list
Description   Displays description of selected measurement
Save selected measurements to file   Saves the list of selected measurement to a text file
 

Privacy Statement  | Terms of Use  | Legal | Contact Us  | © Agilent 2000-2008 