Parameters for RF System Budget Analysis
The recommended way to setup a budget analysis is by using the Budget controller set up dialog box. To open this dialog box, double-click the Budget controller instance from the ADS schematic design. The Budget dialog box includes three tabs, enabling you to define the following aspects of the simulation:
- Setup – Provides simulation setup and results/display setup features.
- Measurements – Provides measurement descriptions, selection, save and recall features.
- Display – Control the visibility of simulation parameters on the Schematic. For details, see Displaying Simulation Parameters on the Schematic.
Setting up a Budget Analysis
The Setup tab enables you to set up the simulation for linear or nonlinear analysis specify the frequency for noise simulation, and to specify how results are output. Names used in netlists and ADS Schematics appear under Parameter Name.
| Setup Dialog Name | Parameter Name | Description | ||
|---|---|---|---|---|
| Simulation - Set up linear/nonlinear simulation | ||||
| Nonlinear Analysis | ||||
| Enable nonlinear analysis | NonlinearAnalysis | Select the checkbox to enable nonlinear analysis. Leave the checkbox unselected to enable linear analysis. | ||
| Harmonic order | NonlinearHarmonicOrder | Harmonic order used for P2D analysis of components that require S-parameter characterization | ||
| Max. component input power (dBm) | CmpMaxPin | Maximum component input power | ||
| Noise Simulation - Set up noise simulation | ||||
| Frequency span | NoiseFreqSpan | The frequency span used for noise simulations | ||
| Frequency step | NoiseFreqStep | The frequency step used for noise simulations. In the dialog box, entering a value for Frequency step automatically calculates the value for Frequency points based on the value for Frequency span. | ||
| Frequency points | Optionally, define the number of points and Frequency span to determine the Frequency step. In the dialog box, entering a value for Frequency points automatically calculates the value for Frequency step based on the value for Frequency span. | |||
| Resolution bandwidth | NoiseResolutionBW | Resolution bandwidth used for noise simulations | ||
| Results - Set up the format and options for displaying results after analysis | ||||
| Components in | TableComponentFormat | Formats output table with measurements in columns or rows | ||
| Angle unit | MeasurementAngleUnit | Determines the angle for output measurements in radians or degrees | ||
| Frequency unit | MeasurementFrequencyUnit | Determines the frequency units for output measurements in Hz, kHz, MHz, GHz, THz, or PHz | ||
| Auto format display with overwrite | AutoFormatDisplay | When selected, the output to the Data Display is formatted in tables and plots such that: - Components are ordered as in the system from first to last (source to term) - Measurements are ordered as listed in the Measurement tab - New data overwrites the existing .dds file for the current design |
||
| Output results as comma separated values (CSV) to file | OutputCSVFile | Measurement data written as comma-separated values to .csv file | ||
| Run command after analysis | RunCommand | When Output results as comma separated values (CSV) to file is selected, enabling this parameter runs a user-defined command after analysis. The command is entered in the System Command field, and typically is used for post processing the .csv file data. | ||
| System command | SystemCommand | When Run command after analysis is selected, enter a command to run, such as running Excel on a PC platform. See Exporting and Post-Processing Results. | ||
Selecting Measurements
The Measurement tab enables you to select the system cascade measurements that are evaluated per component in the schematic design. Names used in netlists and ADS Schematics appear under Parameter Name.
| Note Measurements also include a set of built-in system summary measurements, that evaluate overall system performance. These are single value system measurements and are not for each component. They are not selectable, and are always written to the CSV file and the ADS dataset. |
| Setup Dialog Name | Parameter Name | Description |
|---|---|---|
| Recall selected measurements from file | Populates the list of Selected Measurements from a file | |
| Available Measurements | Select from list of available measurements to include in analysis. These are system cascade measurements for each component, or at each component input or output. | |
| Selected Measurements | Measurement[n] | An ordered list determines the order in which measurements are written to the CSV file and Data Display. To change the order:
|
| Description | Displays description of selected measurement | |
| Save selected measurements to file | Saves the list of selected measurement to a text file |
Privacy
Statement
|
Terms of Use
|
Legal |
Contact Us
|
© Agilent 2000-2008 ![]()